Product Detail : Online tenders are invited for .ROOF FOR LGS COACHES.ROOF COMPLETE LG 16149 ALT b -1 NO.ROOF END PART LG 10180 ALT e 2 NOS WELDING PARTS LG16150 ALT b -1 NO ROOF VENTILATOR LG 16132 ALT NIL - 7 NOS THE FIRM SHALL FULFILL THE REQUIRMENT AS PER ICF MD SPECN.200,ISSUE STATUS 01,REV.02 AND SIDE WALL FOR LGS COACHES LG-14196 ALT a -1NO, LG-14197 ALT a -1NO, LG-14222 ALT NIL -1NO, LG-14221 ALT a -1NO, LG14198 ALT c -1NO, LG14199 ALT c -2NOS, LG14200 ALT c -1NO. LHB DRG NOS. 1 10113.1.20.110.018 ALT A -1NO 1 10113.1.20.110.019 ALT A -1NO.WINDOW BARS ICF STD 1-0-012 ITEM - 65 - 184 NOS,RAINWATER GUTTER LG 10182 ALT a - 6 NOS. THE FIRM SHALL FULFIL THE REQUIREMENT AS PER ICF MD SPECN.200, ISSUE STATUS 01, REV.02.LAVATORY SIDEWALLS TO BE PROVIDED WITH NORMAL WINDOW 610X560 OPENING WITH LIP FORMING INSTEAD OF 680 X 880.WINDOW BARS TO BE WELDED ON SIDEWALL WINDOW OPENINGS.CUTAWAYS FOR WINDOW BAR IN WINDOW LIP PROFILE DELETED.RAINWATER GUTTER TO BE WELDED WITH SIDEWALL AS PER DRG NO.LG 10246 ALT NIL.
Product Detail : Online tenders are invited for ROOF FOR LSCN WCB COACHES ROOF COMPLETE LSCN WCB-1-6-001 COL-I ALT a -1NO. ROOF END PART LR10161 ALT NIL -2NOS, ROOF VENTILATOR LG16132 ALT NIL -7NOS THE FIRM SHALL FULFIL THE REQUIREMENT AS PER ICF MD SPECN.200 ISSUE STATUS 01, REV.02. SIDEWALL FOR LSCN WCB COACHES LSCN WCB-1-4-002 COL-I ALT NIL -1NO, LSCN WCB-1-4-003 COL-I ALT a -1NO, LS14150 ALT NIL -1NO, LS14160 ALT NIL -1NO 1 10113.1.20.110.020 ALT A -1NO, 1 11012.0.20.110.003 ALT NIL -1NO, WINDOW BARS ICF STD-1-0-012 ITEM-65 -136NOS, RAINWATER GUTTER LG10182 ALT a -4NO. THE FIRM SHALL FULFIL THE REQUIREMENT AS PER ICF MD SPECN.200 ISSUE STATUS 01, REV.02 LAVATORY SIDEWALLS TO BE PROVIDED WITH NORMAL WINDOW 610X560 OPENING WITH LIP FORMING INSTEAD OF 680X880, WINDOW BARS TO BE WELDED ON SIDEWALL WINDOW OPENINGS, RAINWATER GUTTER TO BE WELDED WITH SIDEWALL AS PER DRG.NO.LSCN WCB-1-0-001 ALT b .
Product Detail : Online tenders are invited for ROOF FOR LSRD COACHES ROOF COMPLETE LSRD-1-6-001 COL-I ALT b -1NO ROOF END PART LR10161 ALT NIL -2NO, ROOF VENTILATOR LG16132 ALT NIL -7NOS THE FIRM SHALL FULFIL THE REQUIREMENT AS PER ICF MD SPECN.200 ISSUE STATUS 01, REV.02. SIDEWALL FOR LSRD COACHES LSRD-1-4-002 ALT b -1NO, LSRD-1-4-003 ALT b -1NO, LR14375 ALT NIL -1NO, LG14222 ALT NIL -1NO 1 10113.1.20.110.018 ALT A -1NO, 1 10113.1.20.110.019 ALT A -1NO, WINDOW BARS ICF STD-1-0-012 ITEM-65 -140NOS, RAINWATER GUTTER LG10182 ALT a -4NO, RAINWATER GUTTER LR10109 ALT NIL -2NO. THE FIRM SHALL FULFIL THE REQUIREMENT AS PER ICF MD SPECN.200 ISSUE STATUS 01,REV.02. LAVATORY SIDEWALLS TO BE PROVIDED WITH NORMAL WINDOW 610X560 OPENING WITH LIP FORMING INSTEAD OF 680X880 WINDOW BARS TO BE WELDED ON SIDEWALL WINDOW OPENINGS, RAINWATER GUTTER TO BE WELDED WITH SIDEWALL AS PER DRG.NO.LSRD-1-0-001 ALT b .
Product Detail : Online tenders are invited for ROOF FOR LSCN COACHES ROOF COMPLETE LS16100 ALT a -1NO, ROOF ENDPART LG10180 ALT e -2NO, WELDING PARTS LS16149 ALT b -1NO, ROOF VENTILATOR LG16132 ALT NIL -7NOS. THE FIRM SHALL FULFIL THE REQUIREMENT AS PER ICF MD SPECN.200 ISSUE STATUS 01, REV.02 SIDEWALL FOR LSCN COACHES LS14155 ALT b -1NO, LS14159 ALT c -1NO, LS14121 ALT c -1NO, LS14160 ALT NIL -1NO, LS14150 ALT NIL -1NO, 1 10113.1.20.110.018 ALT A -1NO, 1 10113.1.20.110.019 ALT A -1NO. WINDOW BARS ICF STD-1-0-012 ITEM-65 -176NOS RAINWATER GUTTER LG10182 ALT a -4NOS. THE FIRM SHALL FULFIL THE REQUIREMENT AS PER ICF MD SPECN.200 ISSUE STATUS 01, REV.02. LAVATORY SIDEWALLS TO BE PROVIDED WITH NORMAL WINDOW 610X560 OPENING WITH LIP FORMING INSTEAD OF 680X880, WINDOW BARS TO BE WELDED ON SIDEWALL WINDOW OPENINGS. CUTAWAYS FOR WINDOW BAR IN WINDOW LIP PROFILE DELETED. RAINWATER GUTTER TO BE WELDED WITH SIDEWALL AS PER DRG.NO.LS10152 ALT b .
Product Detail : Sealed tenders are invited for Replacement of Battery, Battery charger and charging alternator at Bldg. Mahesail, SK Dighi and Barjumla, Dist: MSD.